国产精品久久久久久久久久久久I超碰青草I中文人妻I国产AV毛片I超碰操操操I蜜桃综合网I欧美7777Ia在线天堂I男女猛烈无遮挡I久青草影院I影音先锋亚洲天堂I国产三级网站I欧美黑人性猛交XXXⅩOI精品人伦一区二区三区I国产又黄又潮娇喘视频在线观看2499 - 黑人一...I蜜桃人妻无码AV天堂三区I成人深夜在线观看免费视频...美女很I欧美人与性动交α欧美精品

歡迎來北京祥生興業科技有限公司!我們將為您提供周到的服務!

產品名稱:類固醇激素校準品

產品型號:72038 72039

產品報價:

產品特點:

供應商:祥生興業規格:7x3ml(lyoph

免費咨詢:13681184382

發郵件給我們:702140183@qq.com

分享到:

72038 72039類固醇激素校準品的詳細資料:

溫馨提示:僅用于科研,不可用于臨床治療

  • 供應商:

    祥生興業

  • 規格:

    7 x 3 ml (lyoph.)


    72038  6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1


    Order no.: 72038
    • 11-Deoxycortisol
    • 21-Deoxycortisol
    • Aldosterone
    • Corticosterone
    • Cortisol
    • Cortisone

    MassChrom® Steroids in Serum/Plasma - LC-MS/MS

    DESCRIPTION

    6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1, lyophilised
    For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.

    These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 1 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
    These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

    TECHNICAL DATA

    Method of Analysis

    LC-MS/MS

    Content

    7 x 3 ml (lyoph.)

    Parameter

    11-Deoxycortisol, 21-Deoxycortisol, Aldosterone, Corticosterone, Cortisol, Cortisone

    Concentrations

    Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

    Substance  Unit Calibrator 1 Calibrator 2 Calibrator 3 Calibrator 4 Calibrator 5 Calibrator 6 Blank Calibrator
    Aldosterone µg/l 0.024 0.084 0.161 0.319 0.816 4.23 n.d. (< 0.014)
    Corticosterone µg/l 0.455 0.997 2.39 4.86 14.9 48.1 n.d. (< 0.175)
    Cortisol µg/l 9.02 20.1 39.1 77.5 149 290 n.d. (< 1.52)
    Cortisone µg/l 0.942 2.56 4.93 9.66 19.5 38.8 n.d. (< 0.148)
    11-Deoxycortisol µg/l 0.088 0.484 0.938 1.87 4.66 13.7 n.d. (< 0.030)
    21-Deoxycortisol µg/l 0.070 0.163 0.257 0.513 1.56 4.69 n.d. (< 0.027)
     
    n.d. = not determined, analytes under LOQ

    Reconstitution

    Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

    Storage conditions

    Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

     

    72039  6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2


    Order no.: 72039
    • 11-Deoxycorticosterone
    • 17-OH-progesterone
    • Androstenedione
    • Dehydroepiandrosterone (DHEA)
    • Dehydroepiandrosterone sulfate (DHEA-S)
    • Dihydrotestosterone (DHT)
    • Estradiol
    • Progesterone
    • Testosterone

    MassChrom® Steroids in Serum/Plasma - LC-MS/MS

    DESCRIPTION

    6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2, lyophilised
    For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.

    These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 2 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
    These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

    TECHNICAL DATA

    Method of Analysis

    LC-MS/MS

    Content

    7 x 3 ml (lyoph.)

    Parameter

    11-Deoxycorticosterone, 17-OH-progesterone, Androstenedione, Dehydroepiandrosterone (DHEA), Dehydroepiandrosterone sulfate (DHEA-S), Dihydrotestosterone (DHT), Estradiol, Progesterone, Testosterone

    Concentrations

    Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

    Substance  Unit Calibrator 1 Calibrator 2 Calibrator 3 Calibrator 4 Calibrator 5 Calibrator 6 Blank Calibrator
    Androstenedione µg/l 0.202 0.408 0.820 1.54 5.09 15.3 n.d. (< 0.020)
    11-Deoxycorticosterone µg/l 0.049 0.098 0.146 0.288 0.721 2.80 n.d. (< 0.023)
    DHEA µg/l 1.04 5.25 10.3 15.6 30.7 60.7 n.d. (< 0.229)
    DHEAS µg/l 117 558 1097 2066 3949 5887 n.d. (< 24.4)
    Dihydrotestosterone µg/l 0.061 0.111 0.257 0.501 0.942 1.50 n.d. (< 0.042)
    Estradiol µg/l 0.043 0.105 0.260 0.530 1.59

    5.33

    n.d. (< 0.026)
    17-Hydroxyprogesterone µg/l 0.097 0.498 1.01 2.00 3.98 15.0 n.d. (< 0.040)
    Progesterone µg/l 0.180 0.805 2.11 5.27 10.3 26.0 n.d. (< 0.030)
    Testosterone µg/l 0.055 0.250 0.982 2.94 5.82 11.6 n.d. (< 0.005)
     n.d. = not determined (< LOQ)

    Reconstitution

    Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

    Storage conditions

    Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

     

溫馨提示:不可用于臨床治療。
 相關同類產品:

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7

版權所有  ICP備案號:京ICP備2024091604號-1 管理登陸 技術支持:化工儀器網   總流量:131184  sitemap.xml