国产精品久久久久久久久久久久I超碰青草I中文人妻I国产AV毛片I超碰操操操I蜜桃综合网I欧美7777Ia在线天堂I男女猛烈无遮挡I久青草影院I影音先锋亚洲天堂I国产三级网站I欧美黑人性猛交XXXⅩOI精品人伦一区二区三区I国产又黄又潮娇喘视频在线观看2499 - 黑人一...I蜜桃人妻无码AV天堂三区I成人深夜在线观看免费视频...美女很I欧美人与性动交α欧美精品

歡迎來北京祥生興業科技有限公司!我們將為您提供周到的服務!
相關文章Related articles
首頁 > 產品中心 > > > 新生兒篩查遺傳代謝疾病研究質譜分析試劑盒

產品名稱:新生兒篩查遺傳代謝疾病研究質譜分析試劑盒

產品型號:55000-57000非衍生化

產品報價:

產品特點:

供應商:Chromsystems祥生興業檢測方法:串聯質譜分析方法LC-MS/MS規格:1set55000MassChrom®AminoAcidsandAcylcarnitines

免費咨詢:13681184382

發郵件給我們:702140183@qq.com

分享到:

55000-57000非衍生化新生兒篩查遺傳代謝疾病研究質譜分析試劑盒的詳細資料:

溫馨提示:僅用于科研,不可用于臨床治療

  • 供應商:

    Chromsystems 祥生興業

  • 檢測方法:

    串聯質譜分析方法LC-MS/MS

  • 規格:

    1set

    新生兒篩查遺傳代謝疾病研究質譜分析試劑盒


  • 55000 MassChrom® Amino Acids and Acylcarnitines, Reagent kit for LC-MS/MS analysis

    • Dried blood spot controls included

    • Multiple diagnoses in a single run

    • High selectivity and sensitivity by MS/MS detection

    • New! Succinylacetone Upgrade Set

    The Chromsystems reagent kit for the determination of amino acids and acylcarnitines from dried blood spot samples using tandem mass spectrometry is intended for the early diagnosis of amino acid and fatty acid metabolic disorders during newborn screening.

    In Germany, newborn screening is regulated by law. Twelve diseases are defined, eight of them to be determined by tandem mass spectrometry. As therapies for only these specific diseases are known, the diagnosis of other diseases is prohibited. Included in these diseases are defects of amino acid metabolism (phenylketonuria and maple syrup urine disease), defects of fatty acid metabolism (Medium and Very Long Chain Acyl-CoA Dehydrogenase Deficiencies) and organoacidurias (isovaleric acidemia). If not detected, these metabolic errors may impair the newborn severely and irreversibly within the first days of its life.57000 MassChrom® Amino Acids and Acylcarnitines/Non Derivatised, Reagent kit for LC-MS/MS analysis



  • 57000 MassChrom® Amino Acids and Acylcarnitines/Non Derivatised, Reagent kit for LC-MS/MS analysis

    • All required and isotope labelled standards included

    • Dried blood spot controls included

    • Direct sample injection without derivatisation

    • High selectivity and sensitivity by MS/MS detection

    This Chromsystems reagent kit allows the very fast and reliable determination of amino acids and acylcarnitines from dried blood spot samples as part of the newborn screening for amino acid and fatty acid metabolic disorders using tandem mass spectrometry. Sample preparation is based on effective extraction of the analytes from the filter card without any further sample preparation steps required. The test utilises stable isotope labelled internal standards for calibration and measurement to ensure reliable and precise quantification of the analytes. Due to the time saving sample preparation and high precision of the MRM method, this direct injection kit stands out from the derivatised method. On the other hand lower sensitivity and interferences from isobaric substances (e.g. C5DC and C6OH) in acylcarnitines analyses may occur.

    This Chromsystems reagent kit allows the very fast and reliable determination of amino acids and acylcarnitines from dried blood spot samples as part of the newborn screening for amino acid and fatty acid metabolic disorders using tandem mass spectrometry. Sample preparation is based on effective extraction of the analytes from the filter card without any further sample preparation steps required. The test utilises stable isotope labelled internal standards for calibration and measurement to ensure reliable and precise quantification of the analytes. Due to the time saving sample preparation and high precision of the MRM method, this direct injection kit stands out from the derivatised method. On the other hand lower sensitivity and interferences from isobaric substances (e.g. C5DC and C6OH) in acylcarnitines analyses may occur.



 相關同類產品:

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7

版權所有  ICP備案號:京ICP備2024091604號-1 管理登陸 技術支持:化工儀器網   總流量:131184  sitemap.xml